|
403718-002
USB interface and cable rackmount kit - Includes cables, bracket and interface - For use with 1U rackmount
|
505836-001
Trusted Platform Module (TPM) 1.2 board - Plugs in socket on the system I/O board - NOTE: this board is not customer replaceable - It is attached to system board with a security rivet
|
519320-001
Disk enclosure - Input-output (I/O) module, SAS interface, small form factor (SFF)
|
519321-001
Backplane board - Includes 25 slots for SAS drives - For HP StorageWorks D2700 Disk Enclosure
|
519322-001
Front power unit identity (UID) interconnect board
|
519323-001
Fan interconnection board - 26AWG 1.7cm (0.66in) long cable assembly
|
662528-001
Power supply backplane board assembly - Vertical board on the front of the power supply bays - Interconnects the power supplies to the system I/O board
|
|
715290-001
Graphics expansion control board - PCI Express, Gen8
|
718577-001
LPe1605 16Gb Fibre Channel HBA for BladeSystem c-Class
|
732715-001
System board Haswell (includes alcohol pads and thermal grease)
|
736859-001
NVIDIA Quadro K6000 Graphics Accelerator board - Requires two PCIe3 x16 slot - Has 12 GB GDDR5 memory with 288GB/sec bandwidth, 2880 CUDA (Compute Unified Device Architecture) cores, and integrated fan - Has two DVI-D port and two DP 1.2 ports
|
|
738770-001
Power/management PCA pass-thru rear FC board
|
744408-001
PCA board Non-Volatile Memory express (NVMe) BL460c Gen9 pass-through DC
|
744409-001
System board (no base pan) - For use with BL460c Gen9
|
744412-001
SAS/SATA Hard drive backplane - For use with BL460c Gen9
|
744413-001
PCA board Non-Volatile Memory express (NVMe) BL460c Gen9 hard disk drive backplane
|
|
756822-001
NVIDIA GRID K2 RAF Graphics Accelerator board - Requires two PCIe3 x16 slot - Has two GK104 GPUs, 8GB GDDR5 total memory (4GB per GPU), 3072 CUDA (Compute Unified Device Architecture) cores, and 8-pin aux power connector
|
761879-001
Smart Array PCIe SAS expansion board - For increased disk storage capacity - Requires one PCIe3 x8 slot - Has nine internal x4 mini-SAS ports (two for connecting to the controller board and up to seven to connect to three drive cages and rear drives)
|
764125-001
1.3TB Workload Accelerator board, Read Intensive (RI) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, value endurance (VE), 0.5 drive writes/day, 1.1PB written
|
764126-001
1.6TB Workload Accelerator board, Read Intensive (RI) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, value endurance (VE), 0.5 drive writes/day, 1.6PB written
|
764127-001
3.2TB Workload Accelerator board, Read Intensive (RI) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, value endurance (VE), 0.5 drive writes/day, 3.1PB written
|
764128-001
6.4TB Workload Accelerator board, Read Intensive (RI) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, full-height, half-length form factor, value endurance (VE), 0.5 drive writes/day, 6.3PB written
|
766915-001
NVIDIA Tesla K40C Graphics Accelerator board - Requires two PCIe3 x16 slot - Has 12GB GDDR5 memory with 288GB/sec bandwidth, 2880 CUDA (Compute Unified Device Architecture) cores, and integrated fan
|
775400-001
System I/O board (motherboard) assembly - For Intel Xeon E5-2600 series v3 processors (Haswell) only - Includes subpan, thermal grease, alcohol pad, and instruction card
|
775401-001
SAS/SATA backplane board - For the front 2-bay small form factor (SFF) hard drive cage - Up to 12Gbs transfer speed - Optional board for configurations requiring more than eight hard drives and no optical drive - Mounts on the rear of the drive cage
|
775402-001
SAS/SATA backplane board - For the front 4-bay large form factor (LFF) hard drive cage - Up to 12Gbs transfer speed - Mounts on the rear of the drive cage
|
775419-001
Secondary PCIe3 riser board ONLY - Provides a full-height x16 PCIe3 in slot 3 of the server - Plugs in the secondary riser slot on the system I/O board - This optional board requires that a second processor be installed
|
775677-001
1.0TB Workload Accelerator board, Mixed Use (MU) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, Light Endurance (LE), 3 drive writes/day, 5.5PB written
|
775678-001
1.3TB Workload Accelerator board, Mixed Use (MU) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, Light Endurance (LE), 3 drive writes/day, 7PB written
|
775679-001
2.6TB Workload Accelerator board, Mixed Use (MU) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, half-height, half-length form factor, Light Endurance (LE), 3 drive writes/day, 14PB written
|
775680-001
5.2TB Workload Accelerator board, Mixed Use (MU) - PCIe board with NAND flash technology and integrated controller - Requires one x8 PCIe (Gen2) slot, full-height, half-length form factor, Light Endurance (LE), 3 drive writes/day, 28PB written
|
777279-001
SAS/SATA backplane board - Mounts on the rear of the 8-bay small form factor (SFF) hard drive cage - Performance is up to 12Gbs transfer speed
|
|